Depuis hier, un nouveau slicer circule dans la communauté Bambu Lab. The OrcaSlicer will open on your screen. Orca slicer has all of them. 1mm, 0. This set works with Prusa Slicer and. 6. g. . PA Start Value. Fix macOS deps build issues. Configure Slicer Settings We’re using PrusaSlicer for this guide, but you can use these steps with any other 3D printing slicer. Maximum Retraction Count – 10. If they don't you'll at least have a basis for what might be wrong. Filament - !!!Dry!!! as others suggested , and filament parameters especially if not using Bambu filament, strongly suggest to use Orca slicer 1. The first stop to eliminate stringing is through a proper retraction setting. (The slicer limits actual speed to keep from exceeding max flow rate, which means the speed settings in process might never be reached. 8 to 1. cfg. Do each step, assess in between if your results match the expectations. I have always used Cura and didnt really have any big problems, but I would like to start. 0 mm; ABS: 0. If you use orca slicer, turn on “avoid crossing walls”. GCode for retraction tower in PrusaSlicer. There is no harm, but long retraction moves can increase the print time. All my printers are configured to use firmware retract so that i can change retract settings during print. Temperature of the filament. 1 is an efficient implementation of the nudged elastic band method (NEB), it's climbing-image variant (NEB-CI) and a new combination that combines NEB, CI-NEB and the OptTS procedure (NEB-TS). Filament - !!!Dry!!! as others suggested , and filament parameters especially if not using Bambu filament, strongly suggest to use Orca slicer 1. However, it is not always easy to make these settings in the slicing software. . Orca Slicer 1. If using a large retraction, consider tuning Klipper's pressure advance instead. . This starts the tuning tower as i can see the response in OctoKlipper. Or use this syntax m140 s {first_layer_bed_temperature [0]} ; bed temp warm. Orca Slicer 1. 2. I’ve seen Youtubers using tiny retraction values of . After the print is complete, we can examine each section of the tower to determine the optimal retraction length for the filament. You will learn how to do this later in this article. 20mm Standard u/BBL X1C0 (modified first layer print speed 25mm/s, first layer infill 105mm/s) Temp Tower: 220c. 10. A good starting point is ten. Then calibrate the flow rate to the actual maximum your filament can do, using the orca slicer calibration tests (my eSUN Silk PLA can do 19mm3/sec comfortably). In Cura, there was a setting for this, but I can't figure. Stepover. But I still see the message on the console. ago I did but I had to go back to Cura. the tower. E-18 is a retraction of 18mm (The minus sign IS important!) A retraction of 18mm should bring the filament clear of the melt zone. WOW! What a difference. log would help since it contains the interpreted config that you are using. Best Ender 3 (V2/Pro/S1) Retraction Settings to Stop Stringing. 4. 6. Even when I try tweaking them printing is a lot slower than with the Elegoo Cura slicer (see below). PLA+ usually is a bit if a hotter temp than PLA, and even with Overture Black PLA I have to do 225 with my 0. This is a custom model and bed texture for the FLSUN Q5. 8 mm; Retraction Speed. 1. G-code generator for 3D printers (Bambu, Prusa, Voron, VzBot, RatRig, Creality, etc. Retraction. Pressure Advance (PA) is a factor that affects your retraction timing. Filament - !!!Dry!!! as others suggested , and filament parameters especially if not using Bambu filament, strongly suggest to use Orca slicer 1. Print about half the speed of PLA to start. The Ender 3 (V2/Pro/S1) printers are great at pushing filament, but stringing can be a problem. If you haven’t checkout out Orca Slicer yet, it comes packed with many helpful calibrations that’ll help you get any filament dialed in. We are always looking for better ways. Fixed several retraction bugs when slicing multicolor models. The best retraction distance for the Ender 3 S1 in Cura: PLA: 0. Even though experimentation will always yield the best results due to differences in hardware, here are the retraction settings of our recommendation that can act as a starting point for printing PLA successfully: Retraction Distance – 5 mm (for Bowden extruders) / 1 mm (Direct Drive) Retraction Speed – 45 mm/s. The different towers all have the same shape and go from 180 to 220 °C for PLA. You can specifically adjust your Outer Wall Line Width in Cura. 7 ( never used this one i use orca slicer) and do flow calibration, advance pressure, Print temperature as an option i do maximum print speed test and retraction test and. You can use a retraction test print (from Thingiverse) to help you get the proper settings for your 3D printer to avoid increasing it much. 3 layer height, it won't need to print as fast but calculations will require the slicer to check. 1 / Tri-ZeroThe best flow rate for the FLSUN Super Racer in Cura: Default value: 100%. Any guidance would be appreciated. File:12 retraction performance test. Print speed is 100, i was more curious about. Bambu Lab X1 Series. 032-0. I set my retraction up to 7mm (CR10 bowden setup) to get a handle on stringing. At first, the Bambu Studio and OrcaSlicer won't seem too different from each. The retraction length is 1. Sorry you’re having all sorts of issues, but for me. Retraction Minimum Travel. 75 mm and a speed of 50 mm/s (for. #2471 opened Oct 20, 2023 by HumbleDeer • Draft. 0 mm retraction at 42 mm/sec - 0% infill. Beeper; Conditional Homing; Conditional QGL; Dump Variables; Get Variable; Hotend Fan RPM Monitoring; LCD RGB; Off; Parking; Pause/Resume, Filament Swaps & Sensors; Replace M109/M190 With TEMPERATURE_WAIT; Shut Down Host; TEST_SPEED; Troubleshooting. 51, again agreeing to sync from the Bambu Cloud. Yes the Bambu slicer has limited basic settings I would recommend the Orca slicer 1. Magarotto. Cura has a little bit of strings but that was because my filament was a bit moist, I dried it again and almost no improvement on the Orca one but next to no strings on the Cura one. I used it with Cura and calibrated the most important settings like print temperature and retraction myself. 2mm, according to your machine spec extruder settings that you’ve shared, and not one that starts an 0mm on the bottom and ends at 2mm on the top. 05mm, 0. 3 or Bambu studio 1. 2 isn't bad. (which are the default Orca Slicer retraction test parameters) Non uniform scaling of the source STL needs to occur to suit certain nozzle/layer combinations. EDIT: It occurs to me that maybe you printed a retraction tower test with a fixed retraction value of 2. In these notes, I’ll summarize simple steps to reduce stringing by calibrating slicer retraction settings. 4mm using Orca Slicer should suffice. 6. I finally found a great solution through the Cura "Calibration Shapes" plugin (you then get all calibration items you would need, such as retraction tower, retraction test, temperature tower, calibration cube, etc). I recently switched over to Orca Slicer. 2. Thanks all for the help!! Check out my 2nd channel, TT Racing: while back, I discovered Orca Slicer, a fork of Bambu Studio that could handle Bamb. I've only found retraction speed. • 10 mo. Orca slicer offers a retraction test. 4 nozzle printing ABS - if you don't mind ringing, or have a finely tuned machine with input shaper, 120mm/s+ is not out of the question. I’ve had a couple successful prints using NinjaTek Chinchilla, which is a 75A TPE filament. (which are the default Orca Slicer retraction test parameters) wootsuit July 23, 2023,. ago. Forgive me if this is not the place to ask. Which for a temp tower might be ok, but for nearly anything else really defeats the purpose of tuning your setup. Flow 105%. Disable any vertical lift feature (such Z-Hop in Cura, a popular slicer). Print test objects to verify the capability of your printer: temp tower, calibration cube, and bridging test, or Bed Level correction tool for advanced users. Qidi xmax3 wifi problems with Orcaslicer. 0 mm; PETG: 0. Reduce Printer Noise. retraction) to make it work for the Ender 3 S1. Once you find a general range, run again with narrower range / finer increment. I think what he meant by "in slicer", you can set Klipper pressure advance command (same one used when you test) in filament profiles in slicer. Get you some basic pla and test it out or download some test parts then you can test your settings out or cut the part up and test those areas that are giving you trouble this way you save on filament and keep a log. 4mm Z Hop Height for a 0. 6. Passing Slicer Variables to a Macro; Useful Macros. Slicer Settings. 3 it has more options and settings. Note that you should use a much lower value (1. However, if one has configured a large retraction in the slicer (eg, 5mm or greater) then one may find they limit the desired speed of retractions. by Gloria E. 2 layer. I wanted to test the retraction with a lower temperature – 195°C. 7 ( never used this one i use orca slicer) and do flow calibration, advance pressure, Print temperature as an option i do maximum print speed test and retraction test and. WOW! What a difference. Orca Slicer stores it as ‚pressure_advanced‘ in the filament json file. Currently using Orca because it has excellent base profiles that need little to no tuning and just some simple adjustments to run on nearly any machine you can think of. stl. Fixed an issue where PA pattern calibration didn't work on delta printers. Running middle of nozzle temp range (250C) Slowed volumetric dispensing (mm^3) to 20. Bed temperature – 70℃. It started printing at high speeds from the first layer and finished quickly, demonstrating the printer’s 250mm/s capabilities. EDIT: It occurs to me that maybe you printed a retraction tower test with a fixed retraction value of 2. Choose the start and end retraction: Use the default values or check the retraction you currently have set in your 3D slicer software as a reference, and enter values above and below the currently set value for retraction distance. imoftendisgruntled. Thanks. I did recognize this after I did almost give up. Ellis' generator is itself adapted from a generator developed by Sineos for Marlin, which is licensed under GNU General Public License, version 3. G1 E-0. A klippy. Scroll down until you get to the part called "Assets. I like to use vision minor adhesive or if you have tpu glue it helps. No jerk No acceleration. first_layer_temperature and first_layer_temperature are vectors, so you will need [] to access them. Pictured result seems… interesting, higher temp yielding fewer strings (look at that 240c section! Clean and virtually no blobs) but more droop(I’d assume worse sticking with supports). First, it crushes constantly when I do simple editing like spliting the model, which is really annoying. But when I increase the flow rate to increase the quality, the dimension is incorrect. Reload to refresh your session. 5 to 1mm, slice and repeat, until stringing just stops. Retraction Speed: It is recommended to test a print at the default 45mm/s and if you notice any issues in the filament, try decreasing the speed by 10mm and stop when you notice improvements. Retraction: 5 mm at 60 mm/s: 4. If you haven’t checkout out Orca Slicer yet, it comes packed with many helpful calibrations that’ll help you get any filament dialed in. Filament - !!!Dry!!! as others suggested , and filament parameters especially if not using Bambu filament, strongly suggest to use Orca slicer 1. EDIT: It occurs to me that maybe you printed a retraction tower test with a fixed retraction value of 2. In Creality print is “combing mode”, I think. 'Process-3' from 5mm - 5. Changed the extrusion widths. 0 mm ; ABS: 0. Fixed several retraction bugs when slicing multicolor models. Example, you test and tune your printer and filament and have the best surface quality at 280 mm/s speed and 25. Retraction wise, I tried Super Slicer retraction towers and got basically the same results as these, except that the models are different. and not one that starts an 0mm on the bottom and ends at 2mm on the top. Please contact the moderators of this subreddit if you have any questions or concerns. 6. The flow rate indicates how much filament is extruded per time unit. For the Ender 3 S1, it is between 40 and 60 mm/s. Slicers ¶ This document provides some tips for configuring a "slicer" application for use with Klipper. Bowden: 0. 9. Click to the edit button, the select the “Extruder” field and change the length as your new one. WARNING speeds at the top of the tower set up to 476mms (slower then bambu x1c normal travel speed) so use at your own risk but you have normally stopped the print well before this. I then also created a new filament profile called “Test” in Orca. 05. Once pressure advance is tuned in Klipper, it may still be useful to configure a small retract value in the slicer (eg, 0. 3 or Bambu studio 1. PETG has a higher melting point than PLA. Choose “Orca Tolerance Test”, then take a look at its X and Y distance, remember them down. The naked truth - Stress Test Full Print Bed by yahbluez. On a similar note, if you already have a great slicer profile for a previous version of the Ender 3, you might want to try to use that as your. Increase retraction distance to 2mm if needed. A nice touch would be able to do the calibration, on a smooth plate, with the LIDAR and then have some way to save the info or at least get the info out. Select the printer, filament, and process you would like to use for the test. One drawback of Orca is that it doesn't do tree support nearly as well as Cura (UltiMaker or Elegoo). Option to allow to remove flow test from build plate. In such situations, setting the retraction length to 0. Auxiliary construction: Skirt (Brim/Raft with very bad adhesion) Fan speed at first layer: 0%. 3mm as the retraction distance. Direct Drive: Start with ~0 to ~0. 7 ( never used this one i use orca slicer) and do flow calibration, advance pressure, Print temperature as an option i do maximum print speed test and retraction test and. How does one set the retraction distance in Orca? I've found the setting for retraction speed but not the distance. . What I already did in Orca, is to create a new printer. . 6mm nozzle and 0. Retraction distance: 2 mm. I switched to slic3r and enabled 'Use firmware retraction' at printer setting. r/klippers. 2 mm works great. 95 to . Click to the edit button, the select the “Extruder” field and change the length as your new one. However, the overhangs are a bit iffy. 6mm Nozzle Changes. Still, you can download a pre-made slicer profile for the Ender 3 (Pro or V2) from popular enthusiasts like Chep and make a few small adjustments (e. Remixes. Alors, nouveau slicer? En fait non, c'est juste un changement de n. Calibrating the flow rate involves a two-step process. If you use the Orca slicer you can add a brim to the tall support tower only . 8-1. Fixed a bug causing "vector too long" issues in some. I downloaded and installed a fresh copy of Studio 1. Command for the Tuning_tower: TUNING_TOWER COMMAND=SET_RETRACTION PARAMETER=RETRACT_LENGTH START=1. 6. You can try it @ 35c and see how it’s working. 6. This distance may be higher if you have a longer bowden tube. After this I did a retraction test and another temp tower, which suggested an even shorter retraction distance and. 5 mm at 50 mm/s: 4-4. folder. In Bambu Studio, open the Printer Profile and look under the extruder tab. Retraction – 2-3 mm at 20 mm/s, though don’t hesitate to drop quite close to zero if stringing is a real issue. I somehow have issues to find a simple tutorial for creating a retraction tower with Prusa slicer. How to print just the part, nothing else. Our Tip: Tune retraction distance up/down by 0. 3 or Bambu studio 1. 2 and I'm getting a lot of stringing. 6. By anyone’s standards that is one big build area, and we are at odds to disagree. 2mm -best I could get printed hex without binding/permanent press fit, 1/4" hex shaft has tight sliding fit on 0. Printing continues as if no retraction had happend. 6. EDIT: It occurs to me that maybe you printed a retraction tower test with a fixed retraction value of 2. Describe the bug The tower needs two bottom shell layers also it has manifold errors but they will repair. 2mm, according to your machine spec extruder settings that you’ve shared, and not one that starts an 0mm on the bottom and ends at 2mm on the top. 4 FACTOR=. For Direct Drive systems: Start with a retraction of 1mm. I recently tried out orcaslicer, and I love a lot of features they have, that Cura doenst have or less accessible. You will have to tune in the retraction and fan speed to suit your machine. My settings are as follows: Standard Overture PLA Temps: 225c Nozzle, 60c Bed Cooling 100% Retraction: . M104 S [first_layer_temperature]; calienta hotend sin esperar. 5mm Z Hop Height with a 0. 2 mm steps and retraction length 2 mm I get 14 rings and it should be 10 rings. 2mm, according to your machine spec extruder settings that you’ve shared, and not one that starts an 0mm on the bottom and ends at 2mm on the top. It hardly takes 1-engineer 1-day to review these. 6. Second, it sometimes produce an vertical edge on the side of a rotating body like a. Easily and with very few grams of material. Some materials may ooze more than others, and may require increased retraction distance & travel speed to achieve. . 2mm, according to your machine spec extruder settings that you’ve shared, and not one that starts an 0mm on the bottom and ends at 2mm on the top. Join me as I share expert tips and undocumented calibration techniques for tuning filament in Orca Slicer. When I print with your settings (eg the hurricane part you shared), the outer wall speed is limited to 15mm/s, even if I set it at 400mm/s. In Cura, you need to edit the Flow value. The aim of the retraction test is to achieve a "cleaner" part without material residues in the movement areas of the hotend. . Using the XY Size compensation, it changes the size of the entire model, proportionally. 5mm. Fixed a regression where the bed type was not remembered and switched when changing. Step: Direct drive: 0. FYI: I don't use bambu studio, therefore I don't know what it really provides etc. The temperature towers are available for different filament types, for example PLA or ABS. ; The available variables are not always published, however, so you sometimes need to dig around to find the names of them. Steps. 3 mm as we’re using a 0. CALC: “retraction = start + measured_height x factor. by Gloria E. Today I show you how to install Orca Slicer! It's free and very fast to install. 5-5. I was wondering why Increasing printing speed does not change to much time to print in orca slicer. . Flow Rate: 0. I wish, Bambu Lab will merge this back to Bambu Studio in the future. You can try it @ 35c and see how it’s working. adamfilipMar 4, 2023. Extruder retraction. The developers forked Bambu Studio (which was a fork of PrusaSlicer which was a. The the retraction step rings do not match the retraction settings or how will you read it correctly ? Expected behavior If I set it to . I print at 50 mm/s with the initial layer at 20 mm/s and the wall speed at 25 mm/s (which are my normal PLA print speeds). 8. Divide 1mm by layer height in mm,. g. If it's not better or still not good enough, reduce the max acceleration. 94 from Bambu seemed low. Please add a Test for tuning Retraction and DeRetraction Calibration (Extra restart) De-retraction is extra important when running with larger nozzles. Yes it is a advanced setting, but it is es setting. 3. Kind of complicated and confusing. We dive a little deeper with some quick tips on Orca Slicer, a fork of Bambu Studios, by SoftFever. I think some people might have been misled. Option 2. A bit outdated as these slicers are changing so fast, but still has good tips and information. . 5mm, which basically eliminated stringing on subsequent prints. Once you have acquired this value, you can enter it in your printer’s configuration file. Best TPU Slicer Settings for Ender 3 V2. You can do this by setting your 3D slicing software to retract the filament while you are driving. 1. 1920 "creality cr 6 se pla profile retraction test by" 3D Models. Extruder Retraction SuperSlicer retraction 3D printer test [Source: Fabbaloo] Stringing is the curse of 3D printing, and with this test you can very quickly identify the retraction length. This test generates a retraction tower automatically. Cura is a 3D slicer with some very neat features. If you want to do something like this you can just import the model, slice it, and then use the slider on the right hand side to go to. Flow rate:0. Find the line that stays most uniform at the speed changes marked by the top two vertical lines. Keep us updated . 3. For normal nozzles, the faster settings are good, so this is a specific case. GCode for retraction tower in PrusaSlicer. Non uniform scaling of the source STL needs to occur to suit certain nozzle/layer combinations. I was using creality slicer. Let me. As we can see, the KLP1 gets no stringing at all until close to the top, so we choose a 0. 05. ago. EDIT: It occurs to me that maybe you printed a retraction tower test with a fixed retraction value of 2. But I don’t really recommend using Creality print. 3. Minimum Extrusion Distance Window – 10 mm. I dried the filament and tested it with a retraction tower and it came out perfect with no stringing at all. This allows you to change the max flow rate in the filament settings which will allow the slicer to use faster speeds. I would also recommend the orca slicer if you are not using it. Thanks to Carl Johnson for this cool retraction calibration tool. Orca Slicer – OctoPrint and Klipper Setup. One glitch I found was caused by using the brand new Bambu Filament PETG-CF in my AMS. AFAIK, it functions as expected without issues since it's part of retraction and not pressure advance. 1) Set your retraction length in Printer Settings, Extruder 1. A fair amount of temp towers, retraction towers and linear acceleration test come with pre-sliced gcode. Basically, it makes sure that your extruded filament bead stays at a consistent width when sudden changes in speed or directions take place. 7 ( never used this one i use orca slicer) and do flow calibration, advance pressure, Print temperature as an option i do maximum print speed test and retraction test and. Reload to refresh your session. Length: 7. Lien de téléchargement : Willkommen zu einem weiteren spannenden 3D-Druck-Abenteuer mit ORCA-Slicer! In diesem brandneuen Video dreht sich alles um die entscheidende Filamentkalibrie. 1 Overview of Maximum Volume Flow Calibration Dimensions. (which are the default Orca Slicer retraction test parameters) Retraction Enabling: First, go to the ‘Travel’ settings and check the ‘Enable Retraction’ box to enable it. PETG benefits from a hot nozzle and a warm build plate to get the best results. One of the best ways to mitigate oozing and stringing is to adjust Ender 3 retraction settings, which is easy to do using a slicer like Cura. 8 F300 ;retraction to help removing waste filament (0. 'Process-3' from 5mm - 5. 3 or Bambu studio 1. If you are looking for the secret to perfect 3d prints, Orca Slicer has buil. Speeds. I am continuing to test different settings and making new profiles, so stay tuned for more filament profiles and more changes in the future. 8 mm ; Retraction Speed. Nov 14, 2022. Printing speed – 60 mm/s. 033 -No photo, but ran line test + tower, very similar ranges (~0.